Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 359
Filtrar
1.
JAMA Cardiol ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38568602

RESUMO

Importance: Arterial hypoxemia, electrolyte imbalances, and periodic breathing increase the vulnerability to cardiac arrhythmia at altitude. Objective: To explore the incidence of tachyarrhythmias and bradyarrhythmias in healthy individuals at high altitudes. Design, Setting, and Participants: This prospective cohort study involved healthy individuals at altitude (8849 m) on Mount Everest, Nepal. Recruitment occurred from January 25 to May 9, 2023, and data analysis took place from June to July 2023. Exposure: All study participants underwent 12-lead electrocardiogram, transthoracic echocardiography, and exercise stress testing before and ambulatory rhythm recording both before and during the expedition. Main Outcome: The incidence of a composite of supraventricular (>30 seconds) and ventricular (>3 beats) tachyarrhythmia and bradyarrhythmia (sinoatrial arrest, second- or third-degree atrioventricular block). Results: Of the 41 individuals recruited, 100% were male, and the mean (SD) age was 33.6 (8.9) years. On baseline investigations, there were no signs of exertional ischemia, wall motion abnormality, or cardiac arrhythmia in any of the participants. Among 34 individuals reaching basecamp at 5300 m, 32 participants climbed to 7900 m or higher, and 14 reached the summit of Mount Everest. A total of 45 primary end point-relevant events were recorded in 13 individuals (38.2%). Forty-three bradyarrhythmic events were documented in 13 individuals (38.2%) and 2 ventricular tachycardias in 2 individuals (5.9%). Nine arrhythmias (20%) in 5 participants occurred when climbers were using supplemental bottled oxygen, whereas 36 events (80%) in 11 participants occurred at lower altitudes when no supplemental bottled oxygen was used. The proportion of individuals with arrhythmia remained stable across levels of increasing altitude, while event rates per 24 hours numerically increased between 5300 m (0.16 per 24 hours) and 7300 m (0.37 per 24 hours) before decreasing again at higher altitudes, where supplemental oxygen was used. None of the study participants reported dizziness or syncope. Conclusion and Relevance: In this study, more than 1 in 3 healthy individuals experienced cardiac arrhythmia during the climb of Mount Everest, thereby confirming the association between exposure to high altitude and incidence of cardiac arrhythmia. Future studies should explore the potential implications of these rhythm disturbances.

2.
J Clin Med ; 13(5)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38592183

RESUMO

Background: Transcatheter aortic valve replacement (TAVR) is a treatment option for severe aortic valve stenosis. Pre-TAVR assessments, extending beyond anatomy, include evaluating frailty. Potential frailty parameters in pre-TAVR computed tomography (CT) scans are not fully explored but could contribute to a comprehensive frailty assessment. The primary objective was to investigate the impact of total muscle area (TMA) and visceral adipose tissue (VAT) as frailty parameters on 5-year all-cause mortality in patients undergoing TAVR. Methods: Between 01/2017 and 12/2018, consecutive TAVR patients undergoing CT scans enabling TMA and VAT measurements were included. Results: A total of 500 patients qualified for combined TMA and VAT analysis. Age was not associated with a higher risk of 5-year mortality (HR 1.02, 95% CI: 0.998-1.049; p = 0.069). Body surface area normalized TMA (nTMA) was significantly associated with 5-year, all-cause mortality (HR 0.927, 95% CI: 0.927-0.997; p = 0.033), while VAT had no effect (HR 1.002, 95% CI: 0.99-1.015; p = 0.7). The effect of nTMA on 5-year, all-cause mortality was gender dependent: the protective effect of higher nTMA was found in male patients (pinteraction: sex × nTMA = 0.007). Conclusions: Normalized total muscle area derived from a routine CT scan before transcatheter aortic valve replacement complements frailty assessment in patients undergoing TAVR.

3.
JACC Cardiovasc Interv ; 17(8): 992-1003, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38658128

RESUMO

BACKGROUND: Extravalvular cardiac damage caused by aortic stenosis affects prognosis after transcatheter aortic valve replacement (TAVR). The long-term impact of changes in cardiac damage in response to relief from mechanical obstruction has not been fully investigated. OBJECTIVES: The authors aimed to investigate changes in cardiac damage early after TAVR and the prognostic impact of the cardiac damage classification after TAVR. METHODS: In this single-center observational study, patients undergoing transfemoral TAVR were retrospectively evaluated for cardiac damage before and after TAVR and classified into 5 stages of cardiac damage (0-4). RESULTS: Among 1,863 patients undergoing TAVR between January 2007 and June 2022, 56 patients (3.0%) were classified as stage 0, 225 (12.1%) as stage 1, 729 (39.1%) as stage 2, 388 (20.8%) as stage 3, and 465 (25.0%) as stage 4. Cardiac stage changed in 47.7% of patients (improved: 30.1% in stages 1-4 and deteriorated: 24.7% in stages 0-3) early after TAVR. Five-year all-cause mortality was associated with cardiac damage both at baseline (HRadjusted: 1.34; 95% CI: 1.24-1.44; P < 0.001 for linear trend) and after TAVR (HRadjusted: 1.40; 95% CI: 1.30-1.51; P < 0.001 for linear trend). Five-year all-cause mortality was stratified by changes in cardiac damage (improved, unchanged, or worsened) in patients with cardiac stage 2, 3, and 4 (log-rank P < 0.001 for stage 2, 0.005 for stage 3, and <0.001 for stage 4). CONCLUSIONS: The extent of extra-aortic valve cardiac damage before and after TAVR and changes in cardiac stage early after TAVR have important prognostic implications during long-term follow-up. (SwissTAVI Registry; NCT01368250).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Fatores de Tempo , Idoso de 80 Anos ou mais , Idoso , Fatores de Risco , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Medição de Risco
5.
Eur J Radiol ; 175: 111425, 2024 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-38490128

RESUMO

PURPOSE: Our study aimed to determine whether 4D cardiac computed tomography (4DCCT) based quantitative myocardial analysis may improve risk stratification and can predict reverse remodeling (RRM) and mortality after transcatheter aortic valve implantation (TAVI). METHODS: Consecutive patients undergoing clinically indicated 4DCCT prior to TAVI were prospectively enrolled. 4DCCT-derived left- (LV) and right ventricular (RV), and left atrial (LA) dimensions, mass, ejection fraction (EF) and myocardial strain were evaluated to predict RRM and survival. RRM was defined by either relative increase in LVEF by 5% or relative decline in LV end diastolic diameter (LVEDD) by 5% assessed by transthoracic echocardiography prior TAVI, at discharge, and at 12-month follow-up compared to baseline prior to TAVI. RESULTS: Among 608 patients included in this study (55 % males, age 81 ± 6.6 years), RRM was observed in 279 (54 %) of 519 patients at discharge and in 218 (48 %) of 453 patients at 12-month echocardiography. While no CCT based measurements predicted RRM at discharge, CCT based LV mass index and LVEF independently predicted RRM at 12-month (ORadj = 1.012; 95 %CI:1.001-1.024; p = 0.046 and ORadj = 0.969; 95 %CI:0.943-0.996; p = 0.024, respectively). The most pronounced changes in LVEF and LVEDD were observed in patients with impaired LV function at baseline. In multivariable analysis age (HRadj = 1.037; 95 %CI:1.005-1.070; p = 0.022) and CCT-based LVEF (HRadj = 0.972; 95 %CI:0.945-0.999; p = 0.048) and LAEF (HRadj = 0.982; 95 %CI:0.968-0.996; p = 0.011) independently predicted survival. CONCLUSION: Comprehensive myocardial functional information derived from routine 4DCCT in patients with severe aortic stenosis undergoing TAVI could predict reverse remodeling and clinical outcomes at 12-month following TAVI.

7.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38479968

RESUMO

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento , Sistema de Registros , Acidente Vascular Cerebral/etiologia
8.
JACC Cardiovasc Interv ; 17(5): 666-677, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38479966

RESUMO

BACKGROUND: Acute ischemic stroke remains a serious complication of transcatheter aortic valve replacement (TAVR). Cerebral embolic protection devices (CEPD) were developed to mitigate the risk of acute ischemic stroke complicating TAVR (AISCT). However, the existing body of evidence does not clearly support CEPD efficacy in AISCT prevention. OBJECTIVES: In a cohort of patients with AISCT, we aimed to compare the characteristics and outcomes of patients who have had unprotected TAVR (CEPD-) vs CEPD-protected TAVR (CEPD+). METHODS: Data were derived from an international multicenter registry focusing on AISCT. We included all patients who experienced ischemic stroke within 72 hours of TAVR. Stroke severity was assessed using the National Institutes of Health Stroke Scale (NIHSS). Primary outcomes were neurologic disability status according to the modified Rankin Score at 30 days, and 6-month all-cause death. Propensity score matched analysis was used to control for differences between groups. RESULTS: In 18,725 TAVR procedures, 416 AISCT (2.2%) within 72 hours were documented, of which 376 were in the CEPD- TAVR group and 40 in the CEPD+ TAVR group. Although the middle cerebral artery stroke rate was similar in both groups (29.7% CEPD- vs 33.3% CEPD+; P = 0.71), AISCT in the CEPD+ group was characterized by a lower rate of internal carotid artery occlusion (0% vs 4.7%) and higher rate of vertebrobasilar system strokes (15.4% vs 5.7%; P = 0.04). AISCT was severe (NIHSS ≥15) in 21.6% CEPD- and 23.3% CEPD+ AISCT (P = 0.20). Disabling stroke rates (modified Rankin Score >1 at 30 days) were 47.3% vs 42.5% (P = 0.62), and 6-month mortality was 31.3% vs 23.3% (P = 0.61), in the CEPD- and CEPD+ groups, respectively. In the propensity score matched cohort, disabling stroke rates were 56.5% vs 41.6% (P = 0.16), and 6-month mortality was 33% vs 19.5% (P = 0.35), in the CEPD- and CEPD+ groups, respectively. CONCLUSIONS: In a large cohort of patients with AISCT, the use of CEPD had little effect on stroke distribution, severity, and outcomes.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , AVC Isquêmico , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , AVC Isquêmico/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
9.
Am J Cardiol ; 216: 9-18, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38301755

RESUMO

Ultrathin-strut drug-eluting stents (DES) have been related to potential improvement in stent-related outcomes compared with thicker-struts DES. However, comparisons among different ultrathin devices are lacking. All randomized controlled trials comparing ultrathin (struts thickness <70 µm) and thicker-struts DESs in an all-comers population were included. Target lesion failure (TLF), as defined by included trials, at 1-year follow-up was the primary end point. Overall mortality, myocardial infarction, target lesion revascularization (TLR), and stent thrombosis were the secondary end points. Arms of included trials were compared using network meta-analysis. Nine studies encompassing 20,081 patients were included, of which 9,509 patients had an ultrathin DES: Orsiro (evaluated in 7 arms with 8,086 patients), MiStent (1 arm with 703 patients), or Supraflex (1 arm with 720 patients). At 1-year follow-up, no significant differences were noted for TLF among these ultrathin DES. In particular, Orsiro was associated with a similar risk of TLF compared with Supraflex (risk rate 1.07, 95% confidence interval 0.59 to 1.78) and showed the highest probability of performing best in terms of TLF, myocardial infarction, and TLR. Ultrathin DES are all associated with a comparable risk of TLF compared with thicker-strut DES. In terms of TLR and TLF risk, Orsiro was the one with the highest probability of best performances, either compared with other ultrathin DES or to devices with thicker struts.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Sirolimo , Metanálise em Rede , Fatores de Risco , Implantes Absorvíveis , Desenho de Prótese , Resultado do Tratamento , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/cirurgia , Stents , Doença da Artéria Coronariana/cirurgia
10.
JACC Cardiovasc Interv ; 17(3): 405-418, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38355269

RESUMO

BACKGROUND: Studies comparing long-term outcomes between non-vitamin K antagonist (VKA) oral anticoagulant agents (direct oral anticoagulant agents [DOACs]) and VKA anticoagulant agents after transcatheter aortic valve replacement (TAVR) are scarce, with conflicting results. OBJECTIVES: The aim of this study was to examine the periprocedural, short-term, and long-term safety and effectiveness of DOACs vs VKAs in patients undergoing TAVR via femoral access with concomitant indications for oral anticoagulation. METHODS: Consecutive patients undergoing transfemoral TAVR in the prospective national SwissTAVI Registry between February 2011 and June 2021 were analyzed. Net clinical benefit (a composite of all-cause mortality, myocardial infarction, stroke, and life-threatening or major bleeding) and the primary safety endpoint (a composite of life-threatening and major bleeding) were compared between the VKA and DOAC groups at 30 days, 1 year, and 5 years after TAVR. RESULTS: After 1:1 propensity score matching, 1,454 patients were available for analysis in each group. There was no significant difference in the rate of the net clinical benefit and the safety endpoints between the groups as assessed at 30 days and 1 and 5 years post-TAVR between VKAs and DOACs. VKAs were associated with significantly higher rates of 1- year (HR: 1.28; 95% CI: 1.01-1.62) and 5-year (HR: 1.25; 95% CI: 1.11-1.40) all-cause mortality. Long-term risk for disabling stroke was significantly lower in the VKA group after excluding periprocedural events (HR: 0.64; 95% CI: 0.46-0.90). CONCLUSIONS: At 5 years after TAVR, VKAs are associated with a higher risk for all-cause mortality, a lower risk for disabling stroke, and a similar rate of life-threatening or major bleeding compared with DOACs. (SwissTAVI Registry; NCT01368250).


Assuntos
Estenose da Valva Aórtica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Anticoagulantes/efeitos adversos , Hemorragia/induzido quimicamente , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fibrinolíticos , Vitamina K , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
11.
Am J Cardiol ; 219: 60-70, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38401656

RESUMO

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).

12.
JACC Cardiovasc Interv ; 17(3): 374-387, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38180419

RESUMO

BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.


Assuntos
Estenose da Valva Aórtica , COVID-19 , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Pandemias , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Resultado do Tratamento , COVID-19/epidemiologia , Sistema de Registros , Fatores de Risco
13.
JACC Cardiovasc Interv ; 17(1): 17-28, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38199749

RESUMO

BACKGROUND: Evidence to support immediate P2Y12 inhibitor loading in ST-segment elevation myocardial infarction (STEMI) is limited. OBJECTIVES: This study sought to compare outcomes of STEMI patients receiving immediate or delayed P2Y12 inhibitor treatment. METHODS: Using data from the prospective Bern-PCI registry between 2016 and 2020, we stratified STEMI patients undergoing percutaneous coronary intervention according to time periods with different institutional recommendations regarding P2Y12 inhibitor pretreatment. In cohort 1 (October 2016-September 2018), immediate P2Y12 inhibitor treatment was recommended. In cohort 2 (October 2018-September 2020), P2Y12 inhibitor treatment was recommended after coronary anatomy was confirmed. The primary endpoint was a composite of major adverse cardiac or cerebrovascular events (MACCEs) defined as all-cause death, recurrent myocardial infarction, stroke, or definite stent thrombosis at 30 days. Sensitivity analysis included only patients in whom these recommendations were followed. RESULTS: Cohort 1 included 1,116 patients; pretreatment was actually given in 708 (63.4%). Cohort 2 included 847 patients; pretreatment was withheld in 798 (94.2%). The mean age was 65 ± 13 years, and 24% were female. Baseline characteristics were well-balanced between groups. The median difference for P2Y12 loading to angiography was 52 minutes between cohort 1 and 2 and 100 minutes between patients receiving vs not receiving pretreatment. Rates of MACCEs were similar between cohort 1 and cohort 2 (10.1% vs 8.1%; adjusted HR: 0.91; 95% CI: 0.65-1.28; P = 0.59) and between patients receiving vs not receiving pretreatment (7.1% vs 8.4%; adjusted HR: 1.17; 95% CI: 0.78-1.74; P = 0.45). CONCLUSIONS: In this cohort study of patients with STEMI undergoing primary percutaneous coronary intervention, P2Y12 inhibitor pretreatment was not associated with improved MACCEs.


Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Estudos de Coortes , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Resultado do Tratamento , Sistema de Registros
14.
EuroIntervention ; 20(1): 95-103, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982161

RESUMO

BACKGROUND: Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS: We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS: Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS: Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS: One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Sistema de Registros , Acidente Vascular Cerebral/etiologia , Desenho de Prótese
15.
Can J Cardiol ; 40(2): 235-249, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37931671

RESUMO

In this narrative review, we aim to summarize the literature surrounding the assessment and management of the common, yet understudied combination of aortic stenosis (AS) and mitral regurgitation (MR), the components of which are complexly inter-related and interdependent from diagnostic, prognostic, and therapeutic perspectives. The hemodynamic interdependency of AS and MR confounds the assessment of the severity of each valve disease, thus underscoring the importance of a multimodal approach integrating valvular and extravalvular indicators of severity. A large body of literature suggests that baseline MR is associated with reduced survival post aortic valve (AV) intervention and that regression of MR post-AV intervention confers a mortality benefit. Functional MR is more likely to regress after AV intervention than primary MR. The respective natural courses of the 2 valve diseases are not synchronized; therefore, significant AS and MR at or above the respective threshold for intervention might not coincide. Surgery is primarily a 1-stop-shop procedure because of a considerable perioperative risk of repeat interventions, whereas transcatheter treatment modalities allow for a more tailored timing of intervention with reassessment of concomitant MR after AV replacement and a potential staged intervention in the absence of MR regression. In summary, AS and MR, when combined, are interlaced into a complex hemodynamic, diagnostic, and prognostic synergy, with important therapeutic implications. Contemporary approaches should consider stepwise intervention by exploiting the advantage of transcatheter options. However, evidence is needed to demonstrate the efficacy of different timing and therapeutic options.


Assuntos
Estenose da Valva Aórtica , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Índice de Gravidade de Doença
16.
Clin Ther ; 46(2): 122-133, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37926630

RESUMO

PURPOSE: The optimal antithrombotic strategy after transcatheter valve interventions is a subject of ongoing debate. Although there is evidence from randomized trials in patients undergoing transcatheter aortic valve replacement (TAVR), current evidence on optimal antithrombotic management after transcatheter mitral or tricuspid valve interventions is sparse. This article appraises the current evidence on this topic. METHODS: This narrative review presents key research findings and guideline recommendations, as well as highlights areas for future research. FINDINGS: After TAVR, randomized trial evidence suggests that single antiplatelet therapy is reasonable for patients without pre-existing indications for oral anticoagulation (OAC). If there is a concurrent indication for OAC, the addition of antiplatelet therapy increases bleeding risk. Whether direct oral anticoagulants achieve better outcomes than vitamin K antagonists is uncertain in this setting. Although OAC has been shown to reduce subclinical leaflet thrombosis (which may progress to structural valve degeneration), bleeding events are unacceptably high. There is a lack of randomized trial data comparing antithrombotic strategies after transcatheter mitral or tricuspid valve replacement or after mitral or tricuspid transcatheter edge-to-edge repair. Single antiplatelet therapy after mitral or tricuspid transcatheter edge-to-edge repair may be appropriate, whereas at least 3 months of OAC is suggested after transcatheter mitral valve replacement or transcatheter tricuspid valve replacement. IMPLICATIONS: Randomized studies are warranted to address the knowledge gaps in antithrombotic therapy after transcatheter valve interventions and to optimize outcomes.


Assuntos
Fibrinolíticos , Inibidores da Agregação Plaquetária , Humanos , Inibidores da Agregação Plaquetária/efeitos adversos , Fibrinolíticos/efeitos adversos , Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Anticoagulantes/efeitos adversos , Hemorragia/induzido quimicamente , Hemorragia/tratamento farmacológico
18.
J Am Heart Assoc ; 13(1): e031847, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38156592

RESUMO

BACKGROUND: The optimal time point of staged percutaneous coronary intervention (PCI) among patients with acute coronary syndrome (ACS) remains a matter of debate. Quantitative flow ratio (QFR) is a novel noninvasive method to assess the hemodynamic significance of coronary stenoses. We aimed to investigate whether QFR could refine the timing of staged PCI of non-target vessels (non-TVs) on top of clinical judgment for patients with ACS. METHODS AND RESULTS: For this cohort study, patients with ACS from Bern University Hospital, Switzerland, scheduled to undergo out-of-hospital non-TV staged PCI were eligible. The primary end point was the composite of non-TV myocardial infarction and urgent unplanned non-TV PCI before planned staged PCI. The association between lowest QFR per patient measured in the non-TV (from index angiogram) and the primary end point was assessed using multivariable adjusted Cox proportional hazards regressions with QFR included as linear or penalized spline (nonlinear) term. QFR was measured in 1093 of 1432 patients with ACS scheduled to undergo non-TV staged PCI. Median time to staged PCI was 28 days. The primary end point occurred in 5% of the patients. In multivariable analysis (1018 patients), there was no independent association between non-TV QFR and the primary end point (hazard ratio, 0.87 [95% CI, 0.69-1.05] per 0.1 increase; P=0.125; nonlinear P=0.648). CONCLUSIONS: In selected patients with ACS scheduled to undergo staged PCI at a median of 4 weeks after index PCI, QFR did not emerge as an independent predictor of non-TV events before planned staged PCI. Thus, this study does not provide conceptual evidence that QFR is helpful to refine the timing of staged PCI on top of clinical judgment. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02241291.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/cirurgia , Estudos de Coortes , Angiografia Coronária , Intervenção Coronária Percutânea/métodos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
Am J Cardiol ; 213: 140-145, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38134979

RESUMO

Transcatheter aortic valve replacement (TAVR) has emerged as a successful treatment option for severe aortic stenosis. However, the long-term outcomes of TAVR in nonagenarians is lacking. We aimed to examine the long-term mortality and quality of life in nonagenarians after TAVR. This is a multicenter, retrospective analysis on patients with severe aortic stenosis who underwent TAVR. Patients were divided into 2 groups: nonagenarians (age ≥90 years) and age <90 years. The Kansas City cardiomyopathy questionnaire (KCCQ) and New York Heart Association (NYHA) scores were compared before and after TAVR. All-cause mortality was compared between both groups at 30 days, 1 year, and 5 years after TAVR using the Cox proportional hazard model. A total of 6,896 patients were included, of whom 591 were nonagenarians. Nonagenarians had a higher Society of Thoracic Surgeons perioperative risk of mortality (8.1 ± 4.6% vs 5.4 ± 4.2%, p <0.001) before TAVR. Both groups were similar in KCCQ and NYHA scores at baseline. At 1 year after TAVR, there was no significant difference in improvement in the KCCQ overall score between those aged <90 years and nonagenarians (-4.76, 95% confidence interval [CI] -11.4 to 1.9, p = 0.161). Similarly, there was no statistically significant difference in improvement in NYHA class between the 2 groups at 1 year (odds ratio 1.07, 95% CI 0.85 to 1.25), p = 0.526). The unadjusted 30-day (3.2% vs 2.7%, hazard ratio 1.11, 95% CI 0.70 to 1.80, p = 0.667) and 5-year (28.0% vs 26.6%, hazard ratio 1.05, 95% CI 0.89 to 1.24, p = 0.60) all-cause mortality were similar between the 2 groups. In conclusion, this study demonstrates an excellent long-term mortality rate at 5 years after TAVR in nonagenarians, comparable to patients younger than 90 years. There is a significant and enduring improvement in functional status in nonagenarians, observed up to 1 year after TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Humanos , Qualidade de Vida , Nonagenários , Resultado do Tratamento , Estudos Retrospectivos , Valva Aórtica/cirurgia , Fatores de Risco
20.
Radiology ; 309(3): e230425, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38085082

RESUMO

Background Transthyretin amyloid cardiomyopathy (ATTR-CM) often coexists with severe aortic stenosis (AS). Although strain analysis from cardiac MRI and echocardiography was demonstrated to predict coexisting ATTR-CM, comparable data from four-dimensional (4D) cardiac CT are lacking despite wide availability. Purpose To evaluate the diagnostic performance of 4D cardiac CT-derived parameters in identifying ATTR-CM in older adults considered for transcatheter aortic valve implantation (TAVI). Materials and Methods This prospective single-center screening study for ATTR-CM included consecutive patients with severe AS considered for TAVI who underwent 4D cardiac CT between August 2019 and August 2021 approximately 1 day before technetium 99m (99mTc) 3,3-diphosphono-1,2-propanodicarboxylic-acid (DPD) scintigraphy. The diagnostic performance of CT-based left ventricular (LV), right ventricular, and left atrial dimensions, ejection fraction (EF), and myocardial strain were evaluated against 99mTc-DPD scintigraphy as the reference standard to identify ATTR-CM. Predictors and an unweighted cardiac CT score were validated with internal bootstrapping. The assignment of variables to the score was based on cutoff values achieving the highest Youden index J. Results Among 263 participants (mean age, 83 years ± 4.6 [SD]; 149 male and 114 female participants), 99mTc-DPD scintigraphy (Perugini grade 2 or 3) confirmed coexisting ATTR-CM in 27 (10.3%). CT-derived LV mass index, LV and LA global longitudinal strain (GLS), and relative apical longitudinal strain each predicted the presence of ATTR-CM with an area under the curve (AUC) of at least 0.70. Implementing these parameters with cutoff values of 81 g/m2 or higher, -14.9% or higher, less than 11.5%, and 1.7 or higher in the CT score, respectively, yielded high diagnostic performance (AUC = 0.89; 95% CI: 0.81, 0.94; P < .001) robust to internal bootstrapping validation (AUC = 0.88; 95% CI: 0.82, 0.94). If two criteria were fulfilled, the sensitivity and specificity in the detection of ATTR-CM were 96.3% (95% CI: 81.0, 99.9) and 58.9% (95% CI: 52.3, 65.2), respectively. Conclusion When compared against 99mTc-DPD scintigraphy as the reference standard, routine 4D cardiac CT in older adults considered for TAVI provided high diagnostic performance in the detection of concomitant ATTR-CM by assessing LV and left atrial GLS, relative apical longitudinal strain, and LV mass index. ClinicalTrials.gov registration no.: NCT04061213 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Tavakoli and Onder in this issue.


Assuntos
Neuropatias Amiloides Familiares , Amiloidose , Estenose da Valva Aórtica , Cardiomiopatias , Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Pré-Albumina , Estudos Prospectivos , Amiloidose/complicações , Tomografia Computadorizada por Raios X , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico por imagem , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Neuropatias Amiloides Familiares/complicações , Neuropatias Amiloides Familiares/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...